5
EA-PS 10080-170 3U为德国EA较新推出的高精度直流电源,在进口直流电源中被广泛用于汽车测试电源等领域。
EA-PS 10080-170 3U产品技术规格书(点击右键另存为)德国EA代理,上海雨芯仪器科技有限公司提供
EA-PS 10080-170 3U Features
Wide range input, 208 V - 480 V +10 % 3ph AC
Active Power-Factor-Correction, typical 0.99
Very high efficiency up to over 96 %
High performance of 15 kW per unit
Voltage from 0 - 60 V up to 0 - 2000 V
Currents from 0 - 20 A up to 0 - 510 A
Flexible power regulated DC output stages
(autoranging)
Regulation mode CV, CC, CP with fast crossover
Digital regulation, high resolution with 16bit ADCs and
DACs, selection of control speed: Normal, Fast, Slow
Color 5“ TFT display with touch control and intuitive user interface
Galvanically isolated Share-Bus for parallel operation of all power classes in the 10000 series
Master-Slave bus for parallel operation of up to 64 units of all power classes in the 10000 series
Command langes and drivers: SCPI and ModBus,LabVIEW, IVIBuild-in Interfaces
USB
Ethernet
Analog
USB Host
Master-Slave-Bus
Share-Bus
Software
EA-Power Control
Optional Interfaces
CAN
CANopen
RS232
Profibus
EtherCAT
Profinet, with one or two ports
Modbus, with one or two ports
Ethernet, with one or two ports
Technical Specifications EA-PS 10080-170 3U DC-Output Voltage range 0 - 80V Ripple rms CV ≤10 mV BW 300 kHz Ripple and noise p-p CV ≤100 mV BW 20 MHz Current range 0 - 170 A Power range *1 0 - 5000 W Output capacity 7790 μF Efficiency up to 94.5% *1 Isolation Negative DC-Pol <-> PE ±600 V DC Positive DC-Pol <-> PE +600 V DC Article number 06230930
*1 ** Power and ** Output voltage
EA-PS 10080-170 3U
General specifications
AC-Input Voltage, Phases 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC (208 V 3ph AC with Derating to 9 kW) Frequency 45-66 Hz Power factor >0.99 Leakage current < 5mA Overvoltage category 2 Pollution degree 2 DC-Output static Load regulation CV ≤0.05% FS (0 - ** load, constant input voltage and constant temperature) Line regulation CV ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) Stability CV ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) Temperature coefficient CV ≤30ppm/°C (Following 30 minutes warm up) Compensation (Remote Sense) ≤5% UNominal Load regulation CC ≤0.1% FS (0 - ** load, constant input voltage and constant temperature) Line regulation CC ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) Stability CC ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) Temperature coefficient CC ≤50ppm/°C (Following 30 minutes warm up) Load regulation CP ≤0.3% FS (0 - ** load, constant input voltage and constant temperature) Load regulation CR ≤0.3% FS + 0.1% FS current (0 - ** load, constant input voltage and constant temperature) Protective functions OVP Overvoltage protection adjustable, 0 - 110% UNominal OCP Overcurrent protection adjustable, 0 - 110% INominal OPP Overpower protection adjustable, 0 - 110% PNominal OT Overtemperature protection, output shuts down in case of insufficient cooling DC-Output dynamic Rise time 10 - CV ≤20 ms Fall time 90 - 10% CV ≤20 ms Rise time 10 - CC ≤10 ms Fall time 90 - 10% CC ≤10 ms Display accuracy Voltage ≤0.05% FS Current ≤0.1% FS Insulation AC-Input to DC-Output 3750 Vrms (1 Minute), creepage >8 mm AC-Input to case (PE) 2500 Vrms DC-Output to case (PE) Depending on the model, see model table DC-Output to Interfaces 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output) Interfaces Digital Built-in, galvanically isolated USB, Ethernet (100 MBit) for communication
1x USB Host for data acquisitionOptional, galvanically isolated CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet Interfaces Analog Built-in, galvanically isolated 15-pole D-Sub Signal range 0 - 10 V or 0 - 5 V (switchable) Inputs U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off Outputs Monitor U and I, alarms, reference voltage, status DC, status CV/CC Accuracy U / I / P / R 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4% Device configuration Parallel operation Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus Safety and EMC Safety EN 61010-1
IEC 61010-1
UL 61010-1
CSA C22.2 No 61010-1
BS EN 61010-1EMC EN 55011, class B
CISPR 11, class B
FCC 47 CFR Part 15B, Unintentional Radiator, class B
EN 61326-1 include tests according to:
- EN 61000-4-2
- EN 61000-4-3
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-6Safety protection class 1 Ingress Protection IP20 Environmental conditions Operating temperature 0 - 50 °C Storage temperature -20 - 70 °C Humidity ≤80% RH, non-condensing Altitude ≤2000 m (≤6600 ft) Mechanical construction Cooling Forced air flow from front to rear, temperature controlled fans Dimensions (B x H x T) 19“ x 3U x 668 mm (Enclosure only, not over all) Weight 32.8 kg (72 lb)