5
Features
Wide range input: 380 V - 480 V, +10%, 3ph AC
Active Power Factor Correction, typical 0.99
Bidirectional power supply, 2-quadrants in source and sink
In load operation, regenerative with energy recovery into the grid
Very high efficiency of up to over 96%
High performance with up to 60 kW per unit
Voltages from 0 - 360 V up to 0 - 2000 V Currents from 0 - 80 A up to 0 - 480 A
Flexible power regulated DC output/input stages (autoranging)
Regulation modes CV, CC, CP, CR with fast crossover
Digital regulation, high resolution with 16bit ADCs and DACs, selection of control speed: Normal, Fast, Slow
Galvanically isolated Share-Bus for parallel operation of all power classes in the 10000 series
Master-Slave-Bus for parallel operation of up to 64 units of all power classes in the 10000 series
Integrated function generator with predefined curves
Predefined automotive test procedures for LV123, LV124 and LV148
Integrated Battery test mode, battery and fuel cell lation
Photovoltaics test mode, EN 50530, MPPT
Command langes and drivers: SCPI and ModBus, LabVIEW,
Built-in interfaces
USB
Ethernet
Analog
Master-Slave-Bus
Share-Bus
USB Front panel
Optional interfaces
CAN
CANopen
RS232
Profibus
EtherCAT
Profinet, with one or two ports
Modbus, with one or two ports
Ethernet, with one or two ports
Software
EA-Power Control EA-Battery Simulator
Options
Water Cooling in stainless steel
Technical data
Technical Specifications EA-PUB 12000-80 6U DC-Output Voltage range 0 - 2000V Ripple rms CV ≤500 mV BW 300 kHz Ripple and noise p-p CV ≤3000 mV BW 20 MHz UMin for IMax (sink) 3.7 V Current range 0 - 80 A Power range *1 0 - 60000 W Resistance range 0.85 Ω - 1350 Ω Output capacity 85 μF Efficiency up to 96.5% *1 Isolation Negative DC-Pol <-> PE ±1500 V DC Positive DC-Pol <-> PE +2000 V DC Article number 01123017
*1 ** Power and ** Output voltage
EA-PUB 12000-80 6U
General specifications
AC-Input Voltage, Phases 380V - 480V ±10%,3ph AC Frequency 45-65 Hz Power factor >0.99 Leakage current < 10mA Phase current ≤110 A @ 400 V AC Overvoltage category 2 Pollution degree 2 DC-Output static Load regulation CV ≤0.05% FS (0 - ** load, constant input voltage and constant temperature) Line regulation CV ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) Stability CV ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) Temperature coefficient CV ≤30ppm/°C (Following 30 minutes warm up) Compensation (Remote Sense) ≤5% UNominal Load regulation CC ≤0.1% FS (0 - ** load, constant input voltage and constant temperature) Line regulation CC ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) Stability CC ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) Temperature coefficient CC ≤50ppm/°C (Following 30 minutes warm up) Load regulation CP ≤0.3% FS (0 - ** load, constant input voltage and constant temperature) Load regulation CR ≤0.3% FS + 0.1% FS current (0 - ** load, constant input voltage and constant temperature) Protective functions OVP Overvoltage protection adjustable, 0 - 110% UNominal OCP Overcurrent protection adjustable, 0 - 110% INominal OPP Overpower protection adjustable, 0 - 110% PNominal OT Overtemperature protection, output shuts down in case of insufficient cooling DC-Output dynamic Rise time 10 - CV ≤10 ms Fall time 90 - 10% CV ≤10 ms Rise time 10 - CC ≤2 ms Fall time 90 - 10% CC ≤2 ms Display accuracy Voltage ≤0.05% FS Current ≤0.1% FS Insulation AC-Input to DC-Output 3750 Vrms (1 Minute), creepage >8 mm AC-Input to case (PE) 2500 Vrms DC-Output to case (PE) Depending on the model, see model table DC-Output to Interfaces 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output) Interfaces Digital Built-in, galvanically isolated USB, Ethernet (100 MBit) for communication
1x USB Host for data acquisitionOptional, galvanically isolated CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet Interfaces Analog Built-in, galvanically isolated 15-pole D-Sub Signal range 0 - 10 V or 0 - 5 V (switchable) Inputs U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off Outputs Monitor U and I, alarms, reference voltage, status DC, status CV/CC Accuracy U / I / P / R 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4% Device configuration Parallel operation Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus Safety and EMC Safety EN 61010-1
IEC 61010-1
UL 61010-1
CSA C22.2 No 61010-1
BS EN 61010-1EMC EN 55011, class B
CISPR 11, class B
FCC 47 CFR Part 15B, Unintentional Radiator, class B
EN 61326-1 include tests according to:
- EN 61000-4-2
- EN 61000-4-3
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-6Safety protection class 1 Ingress Protection IP20 Environmental conditions Operating temperature 0 - 50 °C Storage temperature -20 - 70 °C Humidity ≤80% RH, non-condensing Altitude ≤2000 m (≤6600 ft) Mechanical construction Cooling Forced air flow from front to rear, temperature controlled fans Dimensions (B x H x T) 19“ x 6U x 668 mm (Enclosure only, not over all) Weight 82 kg (180 lb)