5
EA-PS 10750-06 2U为德国EA较新推出的高精度直流电源,在进口直流电源中被广泛用于汽车测试电源等领域。
EA-PS 10750-06 2U产品技术规格书(点击右键另存为)德国EA代理,上海雨芯仪器科技有限公司提供
EA-PS 10750-06 2U Features
Wide range input, 110 V - 240 V +10 % 1ph AC
Active Power-Factor-Correction, typical 0.99
Very high efficiency up to over 95 %
Voltage from 0 - 60 V up to 0 - 1500 V
Currents from 0 - 6 A up to 0 - 120 A
Flexible power regulated DC output stages (autoranging)
Regulation mode CV, CC, CP with fast crossover
Digital regulation, high resolution with 16bit ADCs and DACs, selection of control speed: Normal, Fast, Slow
Color 5“ TFT display with touch control and intuitive user interface
Galvanically isolated Share-Bus for parallel operation of all power classes in the 10000 series
Master-Slave bus for parallel operation of up to 64 units of all power classes in the 10000 series
Command langes and drivers: SCPI and ModBus, LabVIEW, IVIBuild-in Interfaces
USB
Ethernet
Analog
USB Host
Master-Slave-Bus
Share-Bus
Software
EA-Power Control
Optional Interfaces
CAN
CANopen
RS232
Profibus
EtherCAT
Profinet, with one or two ports
Modbus, with one or two ports
Ethernet, with one or two ports
Technical Specifications EA-PS 10750-06 2U DC-Output Voltage range 0 - 750V Ripple rms CV ≤50 mV BW 300 kHz Ripple and noise p-p CV ≤500 mV BW 20 MHz Current range 0 - 6 A Power range *1 0 - 1500 W (0 - 1200 W) Output capacity 40 μF Efficiency up to 95.0% *2 Isolation Negative DC-Pol <-> PE ±1500 V DC Positive DC-Pol <-> PE +2000 V DC Article number 06230945 *1 The value in brackets applies to the state of derating (power reduction) for 110 V AC and 120 V AC grid
*2 ** Power and ** Output voltage
EA-PS 10750-06 2U
General specifications
AC-Input Voltage, Phases 110 V / 120 V / 208 V / 220 V / 230 V / 240 V ±10%, 1ph AC (110 V / 120 V 1ph with Derating, see model table) Frequency 45-66 Hz Power factor >0.99 Leakage current < 3.5mA Overvoltage category 2 Pollution degree 2 DC-Output static Load regulation CV ≤0.05% FS (0 - ** load, constant input voltage and constant temperature) Line regulation CV ≤0.01% FS (110 V - 240 V AC +10% input voltage, constant load and constant temperature) Stability CV ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) Temperature coefficient CV ≤30ppm/°C (Following 30 minutes warm up) Compensation (Remote Sense) ≤5% UNominal Load regulation CC ≤0.1% FS (0 - ** load, constant input voltage and constant temperature) Line regulation CC ≤0.01% FS (110 V - 240 V AC +10% input voltage, constant load and constant temperature) Stability CC ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) Temperature coefficient CC ≤50ppm/°C (Following 30 minutes warm up) Load regulation CP ≤0.3% FS (0 - ** load, constant input voltage and constant temperature) Load regulation CR ≤0.3% FS + 0.1% FS current (0 - ** load, constant input voltage and constant temperature) Protective functions OVP Overvoltage protection adjustable, 0 - 110% UNominal OCP Overcurrent protection adjustable, 0 - 110% INominal OPP Overpower protection adjustable, 0 - 110% PNominal OT Overtemperature protection, output shuts down in case of insufficient cooling DC-Output dynamic Rise time 10 - CV ≤20 ms Fall time 90 - 10% CV ≤20 ms Rise time 10 - CC ≤10 ms Fall time 90 - 10% CC ≤10 ms Display accuracy Voltage ≤0.05% FS Current ≤0.1% FS Insulation AC-Input to DC-Output 3750 Vrms (1 Minute), creepage >8 mm AC-Input to case (PE) 2500 Vrms DC-Output to case (PE) Depending on the model, see model table DC-Output to Interfaces 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output) Interfaces Digital Built-in, galvanically isolated USB, Ethernet (100 MBit) for communication
1x USB Host for data acquisitionOptional, galvanically isolated CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet Interfaces Analog Built-in, galvanically isolated 15-pole D-Sub Signal range 0 - 10 V or 0 - 5 V (switchable) Inputs U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off Outputs Monitor U and I, alarms, reference voltage, status DC, status CV/CC Accuracy U / I / P / R 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4% Device configuration Parallel operation Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus Safety and EMC Safety EN 61010-1
IEC 61010-1
UL 61010-1
CSA C22.2 No 61010-1
BS EN 61010-1EMC EN 55011, class B
CISPR 11, class B
FCC 47 CFR Part 15B, Unintentional Radiator, class B
EN 61326-1 include tests according to:
- EN 61000-4-2
- EN 61000-4-3
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-6Safety protection class 1 Ingress Protection IP20 Environmental conditions Operating temperature 0 - 50 °C Storage temperature -20 - 70 °C Humidity ≤80% RH, non-condensing Altitude ≤2000 m (≤6600 ft) Mechanical construction Cooling Forced air flow from front to rear, temperature controlled fans Dimensions (B x H x T) 19“ x 2U x 462 mm (Enclosure only, not over all) Weight 9,5 kg (21 Lbs) 1500 W unit |12,7 kg (28 Lbs) 3000 W unit